Case Studies:  Compressor Station

A medium sized gas transmission pipeline was constructed in the vicinity of the Great Lakes. One of the compressor stations was, for system hydraulic reasons, located adjacent to a sensitive residential district. The client promised that the facility would be inaudible at the nearest residential sites. Ambient noise surveys indicated that the compressor station facility would have to contribute less than 36 dBA at the fenceline of the property. In conjunction with the gas turbine compressor package supplier an achievable specification for the combustion turbine exhaust and package ventilation systems was derived. Onerous building envelope noise emission limits were developed along with strict limits on the extent of exposed pipework and noise emissions from the gas metering system. Ultra low noise cooling systems for the compressed gas were also required. With the use of VFD’s and the best fans available, compliance with the requirements was achieved.

 

Home ] Services ] Markets ] Case Studies ] Downloads ] About Us ] Links ] Contact Us ]